E100 electromagnetic flowmeter

Product Name: E100 electromagnetic flowmeter

Product Brand: Endress+Hauser

Product Model: E100

Product Introduction

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

  • Measuring range

    4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)

  • Medium temperature range

    –10 to +110 °C (+14 to +230 °F)

  • Max. process pressure

    PN 40, Class 150, 20K

  • Wetted materials

    Liner: PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum