All product categories

ADMAG AXW magnetic flowmeter

Product Name: ADMAG AXW magnetic flowmeter

Product Brand: Yokogawa

Product Model: ADMAG AXW

Product Introduction

 Remote TypeIntegral Type
AXG1A High Grade TransmitterAXW4A TransmitterAXW Integral Type
AXG1A TransmitterAXW150_RF_PTFE-No_Rings_01AXG4A Transmitter  AXW150_RF_PTFE-No_Rings_01AXG4A Transmitter
Accuracy
(Reading Value)
[Sensor Combination]
- AXW: ± 0.35 %
[Sensor Combination]
- AXW: ± 0.35 %
± 0.35 %
Size[Sensor Combination]
- AXW: 25 to 1800 mm
[Sensor Combination]
- AXW: 25 to 1000 mm
25 to 1000 mm
Use[Tansmitter]
- General Purpose 
[Sensor Combination]
- General Purpose
- Explosion Protection
- Submersible
[Tansmitter]
- General Purpose
- Explosion Protection
[Sensor Combination]
- General Purpose
- Explosion Protection
- Submersible
General Purpose
Explosion Protection
Explosion Protection UseIECEx, ATEX, Korea, Brazil (INMETRO), EAC
* Transmitter is usable only in the safety area.
IECEx, ATEX, Korea, Brazil (INMETRO), EAC
Liner MaterialPTFE, Polyurethane, Natural Soft Rubber, Natural Hard Rubber
Communication ProtocolsHART 7, BRAINHART 7, BRAIN, Modbus
FOUNDATION Fieldbus
PROFIBUS PA
EtherNet / IP
Signal Cable Length200 m100 m
Main Function- Easy Setup Wizard
- Trend Graph Display Function
- Data Logging Function (with microSD card)
- Parameter Backup / Restore / Duplication Function (with microSD card)
- Zero Adjustment
- Display Test Function
- Input/Output Test Function
Diagnostic Function[Application Diagnostics]
- Electrode Adhesion Detection
- Sensor Empty Check
- Wiring Connection Diagnosis
- Flow Noise Diagnosis
- Low Conductivity Diagnosis
- Electrode Insulation
- Deterioration Diagnosis
[Application Diagnostics]
- Electrode Adhesion Detection
- Sensor Empty Check
- Wiring Connection Diagnosis
[Verification Function]
- Built-in Verification
- Standard Verification (with FSA130 ADMAG TI Verification Tool)
- Enhanced Verification (with FSA130 ADMAG TI Verification Tool)
Current SignalInput: 1 ch (Active)
Output: 2 ch (Active)
Output: 1 ch (Active)
Pulse/Status SignalOutput: 2 ch (Active [With / Without Internal Resister] / Passive)Output: 2 ch (Active [Without Internal Resister] / Passive)
Status SignalInput: 2 ch (Dry Contact)
Output: 2 ch (Passive)
Input: 1 ch (Dry Contact)
Alarm SignalOutput: 1 ch (Passive)
Multiple LanguagesEnglish, French, German, Italian, Spanish, Portuguese, Russian and Japanese.
Safety Integrity LevelSIL2
Others[AXG1A/AXW4A Transmitter, AXW Integral Type]
 - LCD with improved environmental resistance

[AXG1A Transmitter]
 - Equipped with temperature input terminal for Density correction and Calolie calculation