Product Introduction

The FDU91F ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. Also for flow measurement in open channels and at weirs. Measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Fully welded 316L with hygienic process connection available. Maximum measuring range in liquids 10m (33ft), solids 5m (16ft).

  • Accuracy

    +/- 2 mm + 0.17% of measured distance

  • Process temperature

    -40 °C ... 105 °C
    (-40 °F ... 221 °F)
    CIP: 30 min: 135 °C
    (30 min: 275 °F)

  • Process pressure / max. overpressure limit

    0.7 bar ... 4 bar abs
    (10 psi ... 58 psi)

  • Max. measurement distance

    Liquids: 10 m (33 ft),
    Solids: 5 m (16 ft)

  • Main wetted parts

    316L (fully welded IP68 / NEMA 6P)